What are adducts in mass spectrometry?

What are adducts in mass spectrometry?

Adduct formation is a common ionization method in electrospray ionization mass spectrometry (ESI/MS). Mobile phase additives were found to be a very effective measure for manipulating the formation efficiencies of adducts. An appropriate choice of additive may increase sensitivity by up to three orders of magnitude.

How does ESI work mass spec?

Electrospray ionization (ESI) is a technique used in mass spectrometry to produce ions using an electrospray in which a high voltage is applied to a liquid to create an aerosol. It is especially useful in producing ions from macromolecules because it overcomes the propensity of these molecules to fragment when ionized.

What is positive and negative mode in mass spectrometry?

In the positive ion mode protonated and/or alkali adduct analyte molecules generally observed in the mass spectra. In the negative ion mode operation peaks corresponding to deprotonated analyte molecules are observed. ESI allows production of multiply charged ions.

What is the chemical formula for the most common fragment of formic acid?

CH2O2
Formic acid | CH2O2 | ChemSpider.

What is a base adduct?

Lewis acid-base adduct (Lewis acid-base complex): A molecule formed by the bonding of a Lewis acid with a Lewis base, without simultaneous loss of a leaving group. Reaction of borane (BH3; a Lewis acid) with THF (a Lewis base) occurs when an oxygen lone pair forms an oxygen-boron bond.

How does mass spec identify proteins?

Mass spectrometry (MS) is a commonly used, high-throughput tool for studying proteins. It identifies proteins by generating theoretical spectra in silico from a given protein sequence database and comparing experimental spectra with the theoretical ones to find the closest matches.

What are the three major components of a mass spectrometer?

MSs have three main components: an ion source for ionizing the sample, a magnetic sector for separating the ionized particles according to mass-to-charge ratio (m/z), and a detector. Two methods are used for the ionization of molecules: electron impact (EI) and chemical ionization.

What are the exact masses of ESI adducts?

This list of monoisotopic exact masses of ESI molecular ion adducts was obtained from the Metabolomics Fiehn Lab at UC Davis. The Result column shows an example calculation when M is Taxol, MW = 853.33089

Which is the most common background ion in ESI?

786 (M+Ti)+titanium adduct 798 (2M+NH 4) +diisooctyl phthalate (plasticiser) 803 (2M+Na)+diisooctyl phthalate (plasticiser) ESI- Common Background Ions m/z Ion Compound 26 CN-acetonitrile 45 (HCOO)-formate 59 (CH3CO2)-acetate 69 (CF3CO2Na)-sodium trifluoracetate, TFA 79 PO3-phosphate

How to detect Adduct ions in LC-MS?

You may check out IntelliXtract or esi – a R package for annotation of LC/ESI-MS Mass Signals using xcms. The successful detection of adduct ions requires either pure mass spectra or a deconvolution and peak detection or peak picking step prior adduct assignment.

How are Adduct ions used in electrosprays?

These adduct ions usually give no fragmentation other than the loss of the cation, but for special compounds (e.g., carbohydrates), their fragmentation could be also significantly different from that of [M + H]+ions, giving useful structural information [12].